How to connect and fault find a 1039/50 IPerVoice Gateway

This article outlines how to connect to and fault find for a 1039/50 IPerVoice Gateway


Connections

  • POE device this needs to be connected to a full power POE network port, this needs to be connected to the LAN input port.
  • The BUS Out port needs to be connected to a 1039/20 Riser Power Supply Unit
  • Power On LED needs to be on this shows the 1039/50 has SIP registration to an IPerVoice Server.
  • Video test button - this is used to set the video level within the riser using the video adjustment on the 1039/20’s, this must be turned off for normal use.

NOTE: The purpose of this device is to convert the SIP protocol on the LAN to a Riser Protocol for use in the analogue riser.

Basic Fault Finding:

  • Is the Power Light on if not check the cable between the 1039/50 and the POE Port
  • No Video in Riser Check the video test button on the front of the device