This article shows you what to do with your IPerCom commissioning sheets, for both the call modules (entry panels) and monitors, explaining what each field on the sheets means.
Before filling out your commissioning sheets you will have to print them off in preparation for setting up your new IPerCom system. If you're unsure on how to do this, please refer to the article linked below:
How to prepare before installing a new IPerCom system
Watch the following video which shows you what to do with your MAC address stickers and your commissioning sheets.
Use the tables below to find out more about the parameters (fields) on your commissioning sheets, or both the call modules (entry panels) and monitors. You will need to refer back to these when you configure your IPerCom site using the IPerCom Installer Tool.
Call Modules
Name |
Your chosen name for the Call Module e.g. ‘Main Entrance’. |
Location |
The position within the system Topology (structure) where the entry panel will be programmed. |
Door Used |
If the entry panel lock release relay will be used (e.g. for a pedestrian door) then choose 'Yes'. |
Door Name |
Your chosen name for the door e.g. ‘Main Entrance door’. |
Door Time |
The entry panel lock output relay time. |
Door Forced Alarm |
If the door is opened without a lock release signal from an apartment or from the key reader, an alarm is sent to the concierge switchboard. A door contact must be installed. |
Max Door Opening Time |
Relevant only in systems where a concierge switchboard is installed. If the door is left open for longer than the time set, an alarm is sent to the concierge switchboard. |
Door Under Secret |
If you choose 'Yes' then it will be possible for residents to open the door only after they have been called. This is the recommended setting. |
Gate Used |
As well as the lock release output the entry panel has a dedicated output for an automatic gate. If you will use this output chose 'Yes'. |
Gate Name |
Your chosen name for the gate e.g. ‘car park barrier’. |
Gate Time |
The gate output relay time. |
Gate Under Secret |
If you choose 'Yes' then it will be possible for residents to open the gate only after they have been called. This is the recommended setting. |
Concierge Button |
If this entry panel will call a concierge switchboard choose 'Yes'. |
Monitors
Block |
The block in which a specific monitor will be used e.g., Block 01. |
Stair |
The stair in which the monitor will be used e.g., Stair 01. |
Floor |
On which floor the monitor will be used e.g., Ground Floor. |
Apartment |
The apartment in which the monitor will be used e.g., Apartment 100. |