1740/90 Analogue coax video system monitor connections

This article outlines all of the connections on a 1740/90 Analogue coax video system monitor.

1740-90-1

  1. R1 = OV Monitor supply
  2. R2 = +18V Monitor supply (Only after a call)
  3. V5 = Coax Screen
  4. V3 = Coax inner
  5. CA = Call
  6. 1 = Audio to monitor
  7. 2 = Audio to panel
  8. 6 = Audio 0V
  9. 9 = Lock release