Fault:
The switchboard does not start up.
Solution:
Measure the voltage between terminals “+V” and “0V” of switchboard, if the voltage is lower than +16Vdc, find the reason of voltage drop or short-circuit.
Fault:
The display shows “ERROR DATA LINE”.
Solution:
Measure the voltage between terminals “D” and “0V”, if the voltage is lower than +13,5Vdc, find the reason of voltage drop or short-circuit.