How to set up a 1039/81 secure side relay for IPerVoice

This article tells you how set up a 1039/81 secure side relay in IPerVoice.

 

For Secured by Design application, we need to move the lock release control from the non-secure side of the Entrance Door to the secure side. This is achieved with the use of a 1039/81 IP relay set.

 

1. Connect the 1039/81 to the IPerVoice Network - The device should appear in New Devices

  • Click on configure and name the output relays with the door name they need to be associated with (e.g., Secure Side Relay). 
  • The Time here is the for how long you need the door to be released for - If you're using this as a trigger for a third party access control system then set the time for 1 second.

 

2. Now create a link between the door and the secure side relay:

  • Select the Call Module then the Door on the Call Module and under Special Functions, select Drive on Door 
  • Opening and select the Relay you wish to activate.

 

Click on Confirm and then Update System.