- Home
- Legacy Systems
- IPerVoice
The limits and basic fault finding tips for a 1039/20 IPerVoice Riser PSU
This article provides you with some basic fault finding tips for the 1039/20 Power Supply.
Table of Contents:
Features:
- 230vAC required
- Output 54V DC 650mA 55 Watt
- Thermally fused
- Voltage test terminals
- Video level adjustment (see page 5 of the installation manual attached)
Riser Limits:
- When used with Signo audio handsets, Signo video monitors or Imago video monitors the maximum number of 4-way Decoders is thirty (120 monitors/handsets).
- When used with Folio and Aiko video monitors the maximum number of 4-way Decoders is ten (40 monitors/handsets).
- There is a 90 meter limit between the Power Supply Unit and the furthest monitor.
- Maximum 9 x Power Supply Unit per riser
Basic Faulting Finding:
- Check with a Multi-meter there is correct 230vAC on the input if no voltage check the fused spur
- Check with a Multi-meter there is 54vDC voltage on the output if no voltage remove output wait 2 minutes for the thermal fuse to cool.
- Retest after 2 minutes if still no voltage and 230vAC is present change the unit, there is no programming required for this unit.
1039/20 Datasheet